    "data": {
        "id": 545,
        "sku": "aurora-411-horizontal-single-stage-split-case-pump",
        "name": "Pentair Aurora 411 Horizontal Single Stage Split Case Pump",
        "type": "simple",
        "variations_count": 0,
        "manufacturer": "Pentair",
        "product_url": "https://www.pentair.com/en-us/flow/aurora-brand-page/aurora-products/aurora-411-horizontal-single-stage-split-case-pump.html",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 55,
            "name": "Non-Fire Pumps"
        },
        "categories": [
            {
                "id": 55,
                "name": "Non-Fire Pumps"
            },
            {
                "id": 60,
                "name": "Split Case Pumps"
            }
        ],
        "series": null,
        "specifications": {
            "Split case design": "makes it easy to remove upper casing without disturbing suction and discharge for simpler servicing and inspection.",
            "Dynamically balanced impeller": "is keyed to the shaft and secured by adjustable shaft sleeve.",
            "Bronze shaft sleeve": "extends the entire length of each stuffing box to prevent shaft wear.",
            "Interchangeable stuffing boxes": "come equipped with 303 stainless steel parts and Buna-N® elastomers for a longer pump life.",
            "Mechanical seals": "are included in standard constructions and include carbon against ceramic face for optimal hot water performance.",
            "Grease lubrication bearings": "are conveniently located for quick access and outfitted with oil seals and non-sparking neoprene rotating slingers to protect bearings during operation and washdowns.",
            "High-load bearings": "provide a minimum of 50,000 hours of performance at maximum load thanks to double-row thrust ball bearings and arms that help eliminate misalignment.",
            "Left-hand rotation": "is available with standard parts.",
            "Performance certification": "with positive suction pressure or suction lift is available on each pump for customer approval. All pumps are hydrostatically tested for optimal performance.",
            "Case wearing rings": "prevent wear on pump casing and are easy and cost-effective to replace.",
            "CAPACITIES": "15,000 GPM (3407 M3/HR)",
            "HEADS": "500 Feet (152 Meters)",
            "TEMPERATURES": "275°F (135°C)",
            "Applications Include": "Cooling, Heating and Air Conditioning Service, Boiler Feed Service, Condensate Service, High Pressure Water Service",
            "Brand": "Aurora"
        },
        "images": [
            {
                "src": "https://pentair.weareindata.com/downloaded_assets/pentair/images/ac/1a/ac1a80b96179281bcf1914ec5f31f8cfe05c379755b22b73757a47193a7469ae.png",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/images/ac/1a/ac1a80b96179281bcf1914ec5f31f8cfe05c379755b22b73757a47193a7469ae.png",
                "local_path": "pentair/images/ac/1a/ac1a80b96179281bcf1914ec5f31f8cfe05c379755b22b73757a47193a7469ae.png",
                "original_url": "https://www.pentair.com/content/dam/extranet/web/nam/aurora/images/product-images/400-series/410/pentair-410-split-case-threeqtr-final-beauty-1280x1280.png",
                "is_main": true
            },
            {
                "src": "https://pentair.weareindata.com/downloaded_assets/pentair/images/d8/84/d8840aa8eee7cfaafe3f38bd67a60f07e052a1c896c6fcad968d70c05412ede7.png",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/images/d8/84/d8840aa8eee7cfaafe3f38bd67a60f07e052a1c896c6fcad968d70c05412ede7.png",
                "local_path": "pentair/images/d8/84/d8840aa8eee7cfaafe3f38bd67a60f07e052a1c896c6fcad968d70c05412ede7.png",
                "original_url": "https://www.pentair.com/en-us/flow/aurora-brand-page/aurora-products/aurora-411-horizontal-single-stage-split-case-pump/jcr:content/product-information/additional-media/image.img.png/1760040131314.png",
                "is_main": false
            }
        ],
        "pdf_documents": [
            {
                "text": "Pentair Industrial Power Pumps",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/95/9f/959f032616aed9bdcb5e0b9aaa01fe79b9bf2732a76b05aa3f6e28da107991f3.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/95/9f/959f032616aed9bdcb5e0b9aaa01fe79b9bf2732a76b05aa3f6e28da107991f3.pdf"
            },
            {
                "text": "Aurora 400 Series Split Case Pump - Manual",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/a6/b7/a6b76e09c7275cafed2d7246e30153c38d136a3ca7dd3c7ec52175174bfef0dd.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/a6/b7/a6b76e09c7275cafed2d7246e30153c38d136a3ca7dd3c7ec52175174bfef0dd.pdf"
            },
            {
                "text": "Aurora Models 411, 412, 413, 481 & 483 Split Case Pumps Manual",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/32/52/325219a57bdbe8eb5c608f93e7d19a8e2dfcf82ded5dc8e9637b5e9b81154a95.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/32/52/325219a57bdbe8eb5c608f93e7d19a8e2dfcf82ded5dc8e9637b5e9b81154a95.pdf"
            },
            {
                "text": "Aurora Model 410 Split Case Pump Engineering Data",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/3b/b4/3bb49d94fcbeb273fe009cf07fa0a3044889972317ad9f7b89c00b759daf21d5.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/3b/b4/3bb49d94fcbeb273fe009cf07fa0a3044889972317ad9f7b89c00b759daf21d5.pdf"
            },
            {
                "text": "Aurora 411 Split Case Pump 60hz Performance Curves",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/17/fe/17fe755162eafcaf351e16b53d5bdbeb96496854e30ab475ef1386e43a996f6e.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/17/fe/17fe755162eafcaf351e16b53d5bdbeb96496854e30ab475ef1386e43a996f6e.pdf"
            },
            {
                "text": "Aurora 410 Series 50hz Performance Curves",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/0c/1d/0c1dacacb9aa84dae5375d3e6ce070c24fa462a72bb6fdf5a5408922657c14da.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/0c/1d/0c1dacacb9aa84dae5375d3e6ce070c24fa462a72bb6fdf5a5408922657c14da.pdf"
            },
            {
                "text": "Aurora Model 410 Single Stage Split Case Pump Dimensional Data",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/31/11/3111a59c0e82d098ce78731d42992e88bd19359a6a016397d7cc37b4bef4796a.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/31/11/3111a59c0e82d098ce78731d42992e88bd19359a6a016397d7cc37b4bef4796a.pdf"
            },
            {
                "text": "Aurora Horizontal Split Case Centrifugal Pump - Specifications",
                "type": "document",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/a6/f8/a6f81f2e0445caabee618c49c5164cca58abf3d414e6c8019c66c42820756344.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/a6/f8/a6f81f2e0445caabee618c49c5164cca58abf3d414e6c8019c66c42820756344.pdf"
            },
            {
                "text": "410A Series Split Case Fire Pumps Repair Parts Index",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/d6/1c/d61c40f9b84c2b86f4ceb426bdbb554549529598e3316a4f38c0c679d7b1011e.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/d6/1c/d61c40f9b84c2b86f4ceb426bdbb554549529598e3316a4f38c0c679d7b1011e.pdf"
            },
            {
                "text": "Aurora Models 411, 412, 413, 481 & 483 Split Case Pumps Manual - Español",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/2d/d7/2dd7017d2649a3be8f6101db2525020e8b7067e0ef6266dd1445f3b2404ffe8b.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/2d/d7/2dd7017d2649a3be8f6101db2525020e8b7067e0ef6266dd1445f3b2404ffe8b.pdf"
            },
            {
                "text": "Aurora Repair Part Kits & Assemblies (Legacy Models)",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/0c/bf/0cbf5692dd298df02a4b0e4500d71beca40e6417c1b2abc0d7d2c07602a78b57.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/0c/bf/0cbf5692dd298df02a4b0e4500d71beca40e6417c1b2abc0d7d2c07602a78b57.pdf"
            },
            {
                "text": "Pentair Aurora HVAC Portfolio Sales Flyer",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/f2/87/f28780e1c2719366ccccaa6c56dba2e985f654272ab8e9543efb443f7bd210a6.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/f2/87/f28780e1c2719366ccccaa6c56dba2e985f654272ab8e9543efb443f7bd210a6.pdf"
            },
            {
                "text": "Aurora 400 Series Split Case Pumps Sales Flyer",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/2d/9c/2d9cfefc0cd2ea54173e9193174f4c28ea32b9f127a6f820e0559551d24f2e1c.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/2d/9c/2d9cfefc0cd2ea54173e9193174f4c28ea32b9f127a6f820e0559551d24f2e1c.pdf"
            },
            {
                "text": "Aurora 400 Series Split Case Pumps Brochure",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/b5/ca/b5caadfc7a94180a4fc048d417df7ffb97f654ec44503d7ff5cb06e0bbe77aca.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/b5/ca/b5caadfc7a94180a4fc048d417df7ffb97f654ec44503d7ff5cb06e0bbe77aca.pdf"
            },
            {
                "text": "Aurora Commercial HVAC & Water Supply Pumps Brochure",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/51/a6/51a607d9af3f419a2d591de4cd709ae6f4e3c453eb9013de9c473452f7099fc7.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/51/a6/51a607d9af3f419a2d591de4cd709ae6f4e3c453eb9013de9c473452f7099fc7.pdf"
            },
            {
                "text": "Aurora Split Case Repair Kits Sales Flyer",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/57/b8/57b88a0d3df7e538084c2a9cf8733ce342a77f5b3c8f02627a1c83fb9dda5c6d.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/57/b8/57b88a0d3df7e538084c2a9cf8733ce342a77f5b3c8f02627a1c83fb9dda5c6d.pdf"
            },
            {
                "text": "Aurora Split Case Pumps Repair Kits and Parts Guide (NEW)",
                "type": "pdf",
                "url": "https://pentair.weareindata.com/downloaded_assets/pentair/pdfs/e7/86/e786094b8f7c2817136b6ed989d810442176ea53399cf01486a7d3dfef37fc0d.pdf",
                "original_url": null,
                "local_path": "pentair/pdfs/e7/86/e786094b8f7c2817136b6ed989d810442176ea53399cf01486a7d3dfef37fc0d.pdf"
            }
        ],
        "custom_fields": {
            "family_id": "pentair-aurora-411-horizontal-single-stage",
            "brand": "Aurora",
            "part_numbers": [],
            "business_units": "IFT – Commercial and Infrastructure Flow,IFT – Residential and Irrigation Flow",
            "applications": [
                "Split Case Pumps",
                "Non-Fire Pumps"
            ],
            "discontinued": 0
        },
        "description": "## KEY FEATURES\n\nMore than 90 years ago, Aurora Pump built its business with these reliable and long-lasting pumps. We are still building on our legacy of quality design and manufacturing today.\n\n- Horizontal Split Case Pumps are the Traditional Solution for Handling the Flow of Liquids\n- 411 Models are Horizontally Baseplate Mounted with a Driver Flexibly Coupled to the Pump\n- Design Recommended Where Floor Space is Readily Available and where Flooding is Not Possible\n- Applications Include:\n  - Cooling, Heating and Air Conditioning Service\n  - Boiler Feed Service\n  - Condensate Service\n  - High Pressure Water Service",
        "created_at": "2026-09-01 02:31:06",
        "variations": []
    }
}