Attributes
| Family Id | 3 inch Solids Handling - 3RH/RHX |
|---|---|
| Brand | Myers |
| Part Numbers | 3RH30M2-01, 3RH30M2-21, 3RH30M2-03, 3RH30M2-23, 3RH30M2-43, 3RH30M2-53, 3RH50M2-01, 3RH50M2-21, 3RH50M2-03, 3RH50M2-23, 3RH50M2-43, 3RH50M2-53, 3RH75M2-03, 3RH75M2-23, 3RH75M2-43, 3RH75M2-53 |
| Business Units | IFT – Commercial and Infrastructure Flow,IFT – Residential and Irrigation Flow |
| Applications | Submersible Solids Handling Pumps |
| Discontinued | 0 |
Description
The Pentair Myers 3RH series vortex pump provides smooth, vibration-free operation when operating at heads higher than peak efficiency. This series is for use when difficult fibrous or stringy solids are expected. Available for use in ordinary and hazardous locations.
- Flows up to 315 gpm
- Heads up to 100'
- Speed 3450 RPM
- 3" discharge
- 2" solids capacity
Variations (16)
3RH30M2-01
| Hazardous Location | 3RHX30M2-01 |
|---|---|
| Voltage | 208 |
| Phase | 1 |
| Hertz | 60 |
| Start Amps | 135 |
| Run Amps | 17.9 |
| Service Factor Amps | 23.8 |
| Run kW | 3.5 |
| Service Factor kW | 4.6 |
| Start KVA | 27 |
| Run KVA | 3.6 |
| NEC Code Letter | L |
| Service Factor | 1.2 |
3RH30M2-21
| Hazardous Location | 3RHX30M2-21 |
|---|---|
| Voltage | 230 |
| Phase | 1 |
| Hertz | 60 |
| Start Amps | 75 |
| Run Amps | 15.6 |
| Service Factor Amps | 20.7 |
| Run kW | 3.5 |
| Service Factor kW | 4.6 |
| Start KVA | 17.3 |
| Run KVA | 3.6 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3RH30M2-03
| Hazardous Location | 3RHX30M2-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 66 |
| Run Amps | 9.9 |
| Service Factor Amps | 13.3 |
| Run kW | 3.2 |
| Service Factor kW | 4.3 |
| Start KVA | 22.9 |
| Run KVA | 2.3 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
3RH30M2-23
| Hazardous Location | 3RHX30M2-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 56.6 |
| Run Amps | 8.6 |
| Service Factor Amps | 11.52 |
| Run kW | 3.2 |
| Service Factor kW | 4.3 |
| Start KVA | 22.5 |
| Run KVA | 2.3 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
3RH30M2-43
| Hazardous Location | 3RHX30M2-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 28.3 |
| Run Amps | 4.3 |
| Service Factor Amps | 5.8 |
| Run kW | 3.2 |
| Service Factor kW | 4.3 |
| Start KVA | 22.5 |
| Run KVA | 2.3 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
3RH30M2-53
| Hazardous Location | 3RHX30M2-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 23 |
| Run Amps | 3.5 |
| Service Factor Amps | 4.6 |
| Run kW | 3.2 |
| Service Factor kW | 4.3 |
| Start KVA | 22.9 |
| Run KVA | 2.4 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
3RH50M2-01
| Hazardous Location | 3RHX50M2-01 |
|---|---|
| Voltage | 208 |
| Phase | 1 |
| Hertz | 60 |
| Start Amps | 135 |
| Run Amps | 29.3 |
| Service Factor Amps | 33.4 |
| Run kW | 5.2 |
| Service Factor kW | 5.8 |
| Start KVA | 27 |
| Run KVA | 5.9 |
| NEC Code Letter | F |
| Service Factor | 1.2 |
3RH50M2-21
| Hazardous Location | 3RHX50M2-21 |
|---|---|
| Voltage | 230 |
| Phase | 1 |
| Hertz | 60 |
| Start Amps | 117 |
| Run Amps | 25.5 |
| Service Factor Amps | 29 |
| Run kW | 5.2 |
| Service Factor kW | 5.8 |
| Start KVA | 26.9 |
| Run KVA | 5.9 |
| NEC Code Letter | F |
| Service Factor | 1.2 |
3RH50M2-03
| Hazardous Location | 3RHX50M2-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 82 |
| Run Amps | 17 |
| Service Factor Amps | 19.1 |
| Run kW | 5.2 |
| Service Factor kW | 5.9 |
| Start KVA | 28.4 |
| Run KVA | 4 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3RH50M2-23
| Hazardous Location | 3RHX50M2-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 77 |
| Run Amps | 14.8 |
| Service Factor Amps | 16.6 |
| Run kW | 5.2 |
| Service Factor kW | 5.9 |
| Start KVA | 30.7 |
| Run KVA | 1 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3RH50M2-43
| Hazardous Location | 3RHX50M2-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 38.5 |
| Run Amps | 7.4 |
| Service Factor Amps | 8.3 |
| Run kW | 5.2 |
| Service Factor kW | 5.9 |
| Start KVA | 30.7 |
| Run KVA | 4 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3RH50M2-53
| Hazardous Location | 3RHX50M2-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 34 |
| Run Amps | 5.9 |
| Service Factor Amps | 6.6 |
| Run kW | 5.2 |
| Service Factor kW | 5.9 |
| Start KVA | 33.9 |
| Run KVA | 4 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3RH75M2-03
| Hazardous Location | 3RHX75M2-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 211 |
| Run Amps | 23.6 |
| Service Factor Amps | 31.1 |
| Run kW | 7.4 |
| Service Factor kW | 9.7 |
| Start KVA | 73.1 |
| Run KVA | 5.5 |
| NEC Code Letter | L |
| Service Factor | 1.31 |
3RH75M2-23
| Hazardous Location | 3RHX75M2-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 172 |
| Run Amps | 20.5 |
| Service Factor Amps | 27 |
| Run kW | 7.4 |
| Service Factor kW | 9.7 |
| Start KVA | 68.5 |
| Run KVA | 5.5 |
| NEC Code Letter | L |
| Service Factor | 1.31 |
3RH75M2-43
| Hazardous Location | 3RHX75M2-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 86 |
| Run Amps | 10.3 |
| Service Factor Amps | 13.5 |
| Run kW | 7.4 |
| Service Factor kW | 9.7 |
| Start KVA | 68.5 |
| Run KVA | 5.5 |
| NEC Code Letter | L |
| Service Factor | 1.31 |
3RH75M2-53
| Hazardous Location | 3RHX75M2-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 71.4 |
| Run Amps | 8.2 |
| Service Factor Amps | 10.8 |
| Run kW | 7.4 |
| Service Factor kW | 9.7 |
| Start KVA | 71.1 |
| Run KVA | 5.5 |
| NEC Code Letter | L |
| Service Factor | 1.31 |
Specifications
| Hertz | 60 |
|---|---|
| Brand | Myers |