Attributes
| Family Id | 3 inch Solids Handling - 3R/RX |
|---|---|
| Brand | Myers |
| Part Numbers | 3R30M4-21, 3R30M4-03, 3R30M4-23, 3R30M4-43, 3R30M4-53, 3R50M4-21, 3R50M4-03, 3R50M4-23, 3R50M4-43, 3R50M4-53 |
| Business Units | IFT – Commercial and Infrastructure Flow,IFT – Residential and Irrigation Flow |
| Applications | Submersible Solids Handling Pumps |
| Discontinued | 1 |
Description
The Pentair Myers 3R series pump provides smooth, vibration-free operation and is for use when difficult fibrous or stringy solids are expected.
Available in ordinary and hazardous location.
- Flows up to 330 gpm
- Heads up to 42'
- 3" discharge
- 3" solids capacity
- 3450 and 1750 rpm
Variations (10)
3R30M4-21
| Hazardous Location | 3RX30M4-21 |
|---|---|
| Voltage | 230 |
| Phase | 1 |
| Start Amps | 101 |
| Run Amps | 17.5 |
| Service Factor Amps | 21 |
| Run kW | 2.1 |
| Service Factor kW | 2.5 |
| Start KVA | 23.2 |
| Run KVA | 4 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
3R30M4-03
| Hazardous Location | 3RX30M4-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Start Amps | 66.7 |
| Run Amps | 15 |
| Service Factor Amps | 18 |
| Run kW | 3.5 |
| Service Factor kW | 4.3 |
| Start KVA | 23 |
| Run KVA | 5 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3R30M4-23
| Hazardous Location | 3RX30M4-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Start Amps | 58 |
| Run Amps | 13 |
| Service Factor Amps | 14.4 |
| Run kW | 3.5 |
| Service Factor kW | 4.3 |
| Start KVA | 23 |
| Run KVA | 5 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3R30M4-43
| Hazardous Location | 3RX30M4-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Start Amps | 29 |
| Run Amps | 6 |
| Service Factor Amps | 7.2 |
| Run kW | 3.5 |
| Service Factor kW | 4.3 |
| Start KVA | 23 |
| Run KVA | 5 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3R30M4-53
| Hazardous Location | 3RX30M4-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Start Amps | 21.3 |
| Run Amps | 5 |
| Service Factor Amps | 6 |
| Run kW | 3.5 |
| Service Factor kW | 4.3 |
| Start KVA | 23 |
| Run KVA | 5 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
3R50M4-21
| Hazardous Location | 3RX50M4-21 |
|---|---|
| Voltage | 230 |
| Phase | 1 |
| Start Amps | 141 |
| Run Amps | 34 |
| Service Factor Amps | 41 |
| Run kW | 6.3 |
| Service Factor kW | 7.7 |
| Start KVA | 32.4 |
| Run KVA | 7.8 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
3R50M4-03
| Hazardous Location | 3RX50M4-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Start Amps | 111 |
| Run Amps | 21.6 |
| Service Factor Amps | 26 |
| Run kW | 5.6 |
| Service Factor kW | 6.9 |
| Start KVA | 38.4 |
| Run KVA | 7.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
3R50M4-23
| Hazardous Location | 3RX50M4-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Start Amps | 96 |
| Run Amps | 18 |
| Service Factor Amps | 21.6 |
| Run kW | 5.6 |
| Service Factor kW | 6.9 |
| Start KVA | 38.4 |
| Run KVA | 7.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
3R50M4-43
| Hazardous Location | 3RX50M4-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Start Amps | 48 |
| Run Amps | 9 |
| Service Factor Amps | 10.8 |
| Run kW | 5.6 |
| Service Factor kW | 6.9 |
| Start KVA | 38.4 |
| Run KVA | 7.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
3R50M4-53
| Hazardous Location | 3RX50M4-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Start Amps | 39 |
| Run Amps | 7.2 |
| Service Factor Amps | 8.6 |
| Run kW | 5.6 |
| Service Factor kW | 6.9 |
| Start KVA | 38.4 |
| Run KVA | 7.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
Specifications
| Service Factor | 1.2 |
|---|---|
| Brand | Myers |