Pentair Myers 3R/3RX 3" Solids Handling Pumps

Scraped SKU: myers-3r-3rx-3-inch-solids-handling-pumps 2026-09-01 02:31:07

Attributes

Family Id3 inch Solids Handling - 3R/RX
BrandMyers
Part Numbers3R30M4-21, 3R30M4-03, 3R30M4-23, 3R30M4-43, 3R30M4-53, 3R50M4-21, 3R50M4-03, 3R50M4-23, 3R50M4-43, 3R50M4-53
Business UnitsIFT – Commercial and Infrastructure Flow,IFT – Residential and Irrigation Flow
ApplicationsSubmersible Solids Handling Pumps
Discontinued1

Description

The Pentair Myers 3R series pump provides smooth, vibration-free operation and is for use when difficult fibrous or stringy solids are expected. Available in ordinary and hazardous location. - Flows up to 330 gpm - Heads up to 42' - 3" discharge - 3" solids capacity - 3450 and 1750 rpm

Variations (10)

3R30M4-21

Hazardous Location3RX30M4-21
Voltage230
Phase1
Start Amps101
Run Amps17.5
Service Factor Amps21
Run kW2.1
Service Factor kW2.5
Start KVA23.2
Run KVA4
NEC Code LetterJ
Service Factor1.2

3R30M4-03

Hazardous Location3RX30M4-03
Voltage208
Phase3
Start Amps66.7
Run Amps15
Service Factor Amps18
Run kW3.5
Service Factor kW4.3
Start KVA23
Run KVA5
NEC Code LetterG
Service Factor1.2

3R30M4-23

Hazardous Location3RX30M4-23
Voltage230
Phase3
Start Amps58
Run Amps13
Service Factor Amps14.4
Run kW3.5
Service Factor kW4.3
Start KVA23
Run KVA5
NEC Code LetterG
Service Factor1.2

3R30M4-43

Hazardous Location3RX30M4-43
Voltage460
Phase3
Start Amps29
Run Amps6
Service Factor Amps7.2
Run kW3.5
Service Factor kW4.3
Start KVA23
Run KVA5
NEC Code LetterG
Service Factor1.2

3R30M4-53

Hazardous Location3RX30M4-53
Voltage575
Phase3
Start Amps21.3
Run Amps5
Service Factor Amps6
Run kW3.5
Service Factor kW4.3
Start KVA23
Run KVA5
NEC Code LetterG
Service Factor1.2

3R50M4-21

Hazardous Location3RX50M4-21
Voltage230
Phase1
Start Amps141
Run Amps34
Service Factor Amps41
Run kW6.3
Service Factor kW7.7
Start KVA32.4
Run KVA7.8
NEC Code LetterH
Service Factor1.2

3R50M4-03

Hazardous Location3RX50M4-03
Voltage208
Phase3
Start Amps111
Run Amps21.6
Service Factor Amps26
Run kW5.6
Service Factor kW6.9
Start KVA38.4
Run KVA7.2
NEC Code LetterH
Service Factor1.2

3R50M4-23

Hazardous Location3RX50M4-23
Voltage230
Phase3
Start Amps96
Run Amps18
Service Factor Amps21.6
Run kW5.6
Service Factor kW6.9
Start KVA38.4
Run KVA7.2
NEC Code LetterH
Service Factor1.2

3R50M4-43

Hazardous Location3RX50M4-43
Voltage460
Phase3
Start Amps48
Run Amps9
Service Factor Amps10.8
Run kW5.6
Service Factor kW6.9
Start KVA38.4
Run KVA7.2
NEC Code LetterH
Service Factor1.2

3R50M4-53

Hazardous Location3RX50M4-53
Voltage575
Phase3
Start Amps39
Run Amps7.2
Service Factor Amps8.6
Run kW5.6
Service Factor kW6.9
Start KVA38.4
Run KVA7.2
NEC Code LetterH
Service Factor1.2

Specifications

Service Factor1.2
BrandMyers