Attributes
| Family Id | 12 inch Solids Handling - 12VL/VLX |
|---|---|
| Brand | Myers |
| Part Numbers | 12VL150M8-03, 12VL150M8-23, 12VL150M8-43, 12VL150M8-53, 12VL200M8-03, 12VL200M8-23, 12VL200M8-43, 12VL200M8-53, 12VL250M8-03, 12VL250M8-23, 12VL250M8-43, 12VL250M8-53, 12VL300M8-23, 12VL300M8-43, 12VL300M8-53, 12VL400M6-23, 12VL400M6-43, 12VL400M6-53, 12VL500M6-23, 12VL500M6-43, 12VL500M6-53, 12VL600M6-43, 12VL600M6-53, 12VL750M6-43, 12VL750M6-53 |
| Business Units | IFT – Commercial and Infrastructure Flow,IFT – Residential and Irrigation Flow |
| Applications | Submersible Solids Handling Pumps |
| Discontinued | 1 |
Description
**This Standard Efficient model has been discontinued and replaced with a Premium Efficient Model -** Pentair Myers MPE 12VL(X)P.
The Pentair Myers 12VL series pump is designed for use in high flow, medium head applications. It’s available for use in ordinary and hazardous locations.
- Flows up to 7750 gpm
- Heads up to 72'
- Speed 870 & 1150 RPM
- 12" discharge
- 5-1/4" solids capacity
Variations (25)
12VL150M8-03
| Hazardous Location | 12VLX150M8-03 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 334 |
| Run Amps | 53.4 |
| Service Factor Amps | 61.2 |
| Run kW | 13.4 |
| Service Factor kW | 15.8 |
| Start KVA | 116 |
| Run KVA | 18.5 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
12VL150M8-23
| Hazardous Location | 12VLX150M8-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 290 |
| Run Amps | 46.4 |
| Service Factor Amps | 53.2 |
| Run kW | 13.4 |
| Service Factor kW | 15.8 |
| Start KVA | 116 |
| Run KVA | 18.5 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
12VL150M8-43
| Hazardous Location | 12VLX150M8-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 145 |
| Run Amps | 23.2 |
| Service Factor Amps | 26.6 |
| Run kW | 13.4 |
| Service Factor kW | 15.8 |
| Start KVA | 116 |
| Run KVA | 18.5 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
12VL150M8-53
| Hazardous Location | 12VLX150M8-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 116 |
| Run Amps | 18.6 |
| Service Factor Amps | 21.3 |
| Run kW | 13.4 |
| Service Factor kW | 15.8 |
| Start KVA | 116 |
| Run KVA | 18.5 |
| NEC Code Letter | J |
| Service Factor | 1.2 |
12VL200M8-03
| Hazardous Location | 12VLX200M8-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 334 |
| Run Amps | 67.2 |
| Service Factor Amps | 78.5 |
| Run kW | 17.6 |
| Service Factor kW | 20.9 |
| Start KVA | 116 |
| Run KVA | 23.2 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL200M8-23
| Hazardous Location | 12VLX200M8-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 290 |
| Run Amps | 63.6 |
| Service Factor Amps | 76.3 |
| Run kW | 17.6 |
| Service Factor kW | 20.9 |
| Start KVA | 116 |
| Run KVA | 23.2 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL200M8-43
| Hazardous Location | 12VLX200M8-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 145 |
| Run Amps | 31.8 |
| Service Factor Amps | 38.1 |
| Run kW | 17.6 |
| Service Factor kW | 20.9 |
| Start KVA | 116 |
| Run KVA | 23.2 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL200M8-53
| Hazardous Location | 12VLX200M8-43 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 116 |
| Run Amps | 23.3 |
| Service Factor Amps | 27.3 |
| Run kW | 17.6 |
| Service Factor kW | 20.9 |
| Start KVA | 116 |
| Run KVA | 23.2 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL250M8-03
| Hazardous Location | 12VLX250M8-03 |
|---|---|
| Voltage | 208 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 501 |
| Run Amps | 84.2 |
| Service Factor Amps | 101 |
| Run kW | 21.2 |
| Service Factor kW | 26.4 |
| Start KVA | 175 |
| Run KVA | 29.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
12VL250M8-23
| Hazardous Location | 12VLX250M8-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 436 |
| Run Amps | 73.2 |
| Service Factor Amps | 87.8 |
| Run kW | 21.2 |
| Service Factor kW | 26.4 |
| Start KVA | 175 |
| Run KVA | 29.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
12VL250M8-43
| Hazardous Location | 12VLX150M8-03 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 218 |
| Run Amps | 36.6 |
| Service Factor Amps | 44 |
| Run kW | 21.2 |
| Service Factor kW | 26.4 |
| Start KVA | 175 |
| Run KVA | 29.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
12VL250M8-53
| Hazardous Location | 12VLX250M8-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 174 |
| Run Amps | 29.3 |
| Service Factor Amps | 35.1 |
| Run kW | 21.2 |
| Service Factor kW | 26.4 |
| Start KVA | 175 |
| Run KVA | 29.2 |
| NEC Code Letter | H |
| Service Factor | 1.2 |
12VL300M8-23
| Hazardous Location | 12VLX300M8-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 436 |
| Run Amps | 88 |
| Service Factor Amps | 105.6 |
| Run kW | 26.4 |
| Service Factor kW | 31.6 |
| Start KVA | 175 |
| Run KVA | 35.1 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL300M8-43
| Hazardous Location | 12VLX300M8-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 218 |
| Run Amps | 44 |
| Service Factor Amps | 52.8 |
| Run kW | 26.4 |
| Service Factor kW | 31.6 |
| Start KVA | 175 |
| Run KVA | 35.1 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL300M8-53
| Hazardous Location | 12VLX300M8-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 174 |
| Run Amps | 35.2 |
| Service Factor Amps | 42.2 |
| Run kW | 36.4 |
| Service Factor kW | 31.6 |
| Start KVA | 175 |
| Run KVA | 35.1 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL400M6-23
| Hazardous Location | 12VLX400M6-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 580 |
| Run Amps | 120.4 |
| Service Factor Amps | 144.4 |
| Run kW | 34.3 |
| Service Factor kW | 41.2 |
| Start KVA | 230 |
| Run KVA | 44 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL400M6-43
| Hazardous Location | 12VLX400M6-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 290 |
| Run Amps | 60.2 |
| Service Factor Amps | 72.2 |
| Run kW | 34.3 |
| Service Factor kW | 41.2 |
| Start KVA | 230 |
| Run KVA | 44 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL400M6-53
| Hazardous Location | 12VLX400M6-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 232 |
| Run Amps | 44.2 |
| Service Factor Amps | 53 |
| Run kW | 34.3 |
| Service Factor kW | 44.2 |
| Start KVA | 230 |
| Run KVA | 44 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL500M6-23
| Hazardous Location | 12VLX500M6-23 |
|---|---|
| Voltage | 230 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 417 |
| Run Amps | 138 |
| Service Factor Amps | 165.6 |
| Run kW | 42.6 |
| Service Factor kW | 51.4 |
| Start KVA | 290 |
| Run KVA | 63.3 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL500M6-43
| Hazardous Location | 12VLX500M6-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 363 |
| Run Amps | 73 |
| Service Factor Amps | 87.6 |
| Run kW | 42.6 |
| Service Factor kW | 51.4 |
| Start KVA | 290 |
| Run KVA | 63.3 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL500M6-53
| Hazardous Location | 12VLX500M6-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 290 |
| Run Amps | 55.2 |
| Service Factor Amps | 66.2 |
| Run kW | 42.6 |
| Service Factor kW | 51.4 |
| Start KVA | 290 |
| Run KVA | 63.3 |
| NEC Code Letter | G |
| Service Factor | 1.2 |
12VL600M6-43
| Hazardous Location | 12VLX600M6-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 405 |
| Run Amps | 84 |
| Service Factor Amps | 101 |
| Run kW | 51.4 |
| Service Factor kW | 62.7 |
| Start KVA | 323 |
| Run KVA | 65.9 |
| NEC Code Letter | F |
| Service Factor | 1.2 |
12VL600M6-53
| Hazardous Location | 12VLX600M6-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 324 |
| Run Amps | 69 |
| Service Factor Amps | 82.8 |
| Run kW | 51.4 |
| Service Factor kW | 62.7 |
| Start KVA | 323 |
| Run KVA | 65.9 |
| NEC Code Letter | F |
| Service Factor | 1.2 |
12VL750M6-43
| Hazardous Location | 12VLX750M6-43 |
|---|---|
| Voltage | 460 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 490 |
| Run Amps | 103 |
| Service Factor Amps | 124 |
| Run kW | 66 |
| Service Factor kW | 79 |
| Start KVA | 390 |
| Run KVA | 82.1 |
| NEC Code Letter | F |
| Service Factor | 1.2 |
12VL750M6-53
| Hazardous Location | 12VLX750M6-53 |
|---|---|
| Voltage | 575 |
| Phase | 3 |
| Hertz | 60 |
| Start Amps | 392 |
| Run Amps | 84 |
| Service Factor Amps | 101 |
| Run kW | 66 |
| Service Factor kW | 79 |
| Start KVA | 390 |
| Run KVA | 82.1 |
| NEC Code Letter | F |
| Service Factor | 1.2 |
Specifications
| Hertz | 60 |
|---|---|
| Phase | 3 |
| Service Factor | 1.2 |
| Brand | Myers |