Pentair Sta-Rite ST.E.P. Plus Series Stainless Steel 4" High-Head Filtered Effluent Pumps

Scraped SKU: sta-rite-st-e-p-plus-series-stainless-steel-4-high-head-filtered-effluent-pumps 2026-09-01 02:31:07

Attributes

Family Idpentair-sta-rite-st-e-p-plus-series-high-head-filtered-effluent-pumps-stainless-steel-10-50-gpm
BrandSta-Rite
Part Numbers
STEP10, STEP10X100FT-05121, STEP10X30FT, STEP10X50FT, STEP20, STEP20X30FT, STEP20X50FT, STEP30-05121, STEP30X30-05121, STEP30X50-05121, STEP30-05221, STEP30X100-05221, STEP30X30-05221, STEP30X50-05221, STEP30-10221, STEP30X100-10221, STEP30X30-10221, STEP30X50-10221, STEP30-15221, STEP30X100-15221, STEP30X30-15221, STEP30X50-15221, STEP50-05121, STEP50-05221, STEP50-10221, STEP50X100FT-10221, STEP50X30FT-10221, STEP50X50FT-10221, STEP50-15221, STEP50X100FT-15221, STEP50X30FT-15221, STEP50X50FT-15221
Business UnitsIFT – Commercial and Infrastructure Flow,IFT – Residential and Irrigation Flow,IFT – Industrial Filtration,IFT – Food and Beverage
ApplicationsEffluent Pumps, Consumer Water Disposal Pumps
Discontinued0

Description

The STEP Plus 4” submersible filtered effluent pumps in 10, 20, 30 and 50 GPM models offer dependable performance and value for high pressure filtered effluent applications. These STEP Plus pumps will handle “dry run” conditions. The 10, 20, 30 and 50 GPM are industry standard 3-3/4” in diameter. ## KEY FEATURES - Proven “Floating Impeller” Staging System – Incorporates 1st-in-class performance, sand handling and thrust management staging system with the industry exclusive “dry-run” design element. Reinforced engineered composites and stainless steel, offering high resistance to corrosion and abrasion. - Discharge – Tested-tough, fiberglass-reinforced thermoplastic, with proven internal check valve. Large wrench flats and rope hole. - Shell – Stainless steel pump shell offers high corrosion resistance. - Shaft – Hexagonal 3/8”, 300-grade stainless steel pump shaft; offers generous impeller drive surfaces. - Shaft Bearing – Exclusive self-lubricating Nylatron bearing resists wear surface from sand. - Motor Bracket – Tested-tough, fiberglass-reinforced thermoplastic; incorporates an integral suction screen.

Variations (32)

STEP10

Horsepower1/2
Stages7
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length10'

STEP10X100FT-05121

Horsepower1/2
Stages7
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length100'

STEP10X30FT

Horsepower1/2
Stages7
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length30'

STEP10X50FT

Horsepower1/2
Stages7
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length50'

STEP20

Horsepower1/2
Stages5
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length10'

STEP20X30FT

Horsepower1/2
Stages5
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length30'

STEP20X50FT

Horsepower1/2
Stages5
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length50'

STEP30-05121

Horsepower1/2
Stages3
MAX LOAD AMPS9.5
VOLTAGES115
Phase Cycles1/60
Cord Length10'

STEP30X30-05121

Horsepower1/2
Stages3
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length30'

STEP30X50-05121

Horsepower1/2
Stages3
MAX LOAD AMPS12.0
VOLTAGES115
Phase Cycles1/60
Cord Length50'

STEP30-05221

Horsepower1/2
Stages3
MAX LOAD AMPS4.7
VOLTAGES230
Phase Cycles1/60
Cord Length10'

STEP30X100-05221

Horsepower1/2
Stages3
MAX LOAD AMPS4.7
VOLTAGES230
Phase Cycles1/60
Cord Length100'

STEP30X30-05221

Horsepower1/2
Stages3
MAX LOAD AMPS4.7
VOLTAGES230
Phase Cycles1/60
Cord Length30'

STEP30X50-05221

Horsepower1/2
Stages3
MAX LOAD AMPS4.7
VOLTAGES230
Phase Cycles1/60
Cord Length50'

STEP30-10221

Horsepower1
Stages5
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length10'

STEP30X100-10221

Horsepower1
Stages5
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length100'

STEP30X30-10221

Horsepower1
Stages5
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length30'

STEP30X50-10221

Horsepower1
Stages5
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length50'

STEP30-15221

Horsepower1-1/2
Stages6
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length10'

STEP30X100-15221

Horsepower1-1/2
Stages6
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length100'

STEP30X30-15221

Horsepower1-1/2
Stages6
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length30'

STEP30X50-15221

Horsepower1-1/2
Stages6
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length50'

STEP50-05121

Horsepower1/2
Stages2
MAX LOAD AMPS9.1
VOLTAGES115
Phase Cycles1/60
Cord Length10'

STEP50-05221

Horsepower1/2
Stages2
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length10'

STEP50-10221

Horsepower1
Stages3
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length10'

STEP50X100FT-10221

Horsepower1
Stages3
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length100'

STEP50X30FT-10221

Horsepower1
Stages3
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length30'

STEP50X50FT-10221

Horsepower1
Stages3
MAX LOAD AMPS9.1
VOLTAGES230
Phase Cycles1/60
Cord Length50'

STEP50-15221

Horsepower1-1/2
Stages4
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length10'

STEP50X100FT-15221

Horsepower1-1/2
Stages4
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length100'

STEP50X30FT-15221

Horsepower1-1/2
Stages4
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length30'

STEP50X50FT-15221

Horsepower1-1/2
Stages6
MAX LOAD AMPS11.0
VOLTAGES230
Phase Cycles1/60
Cord Length50'

Specifications

Phase Cycles1/60
BrandSta-Rite

PDF Documents